We discovered these guidelines after investigating more than 500 LED projects.

We discovered these guidelines after investigating more than 500 LED projects.

As more and more people utilise LED screens as display devices, the market share of conventional LCD displays has been steadily taken over by the LED display sector, and it is now the preferred option for display devices in many locations. LED display installation techniques vary depending on the environment and application industry. As an LED display manufacturer, we looked around 500 LED project examples and compiled the following standard practises and safety measures for LED display installation! Let's jump right to the point!

The primary focus of this article is the introduction of seven widely used installation techniques: wall-mounted design, floor-standing design, embedded design, upright design, column, hoisting design, and F cantilever/truss. According to the figure:

Wall-mounted design

We discovered these guidelines after investigating more than 500 LED projects.

1) Both indoors and outdoors can use this installation technique.

2) It can be used in conference rooms, lecture halls, events, stadiums, and other settings.

3) Indoor screens typically don't have a maintenance area. It frequently uses front maintenance design and minimal spacing. Although the screen is small and thin, some lecture halls and other locations where large-area displays are utilised may benefit from rear maintenance design, which can reserve adequate space for maintenance behind the screen to aid in heat dissipation and screen maintenance.

4) The back maintenance design is typically used for outdoor screens. In order to maintain the outdoor screen, which is simple to maintain and may be installed with heat dissipation equipment due to its high brightness and heat output and the fact that the outdoor temperature is higher than the indoor temperature, adequate space must be set aside behind the screen.

Floor-standing design

We discovered these guidelines after investigating more than 500 LED projects.

1) Both indoors and outdoors can use this installation technique.
2) It is suited to venues such as malls, assembly halls, lecture halls, and others.
3) Indoor screens typically employ a front maintenance design, which can be used to walls that are too big or too light to bear force. The wall and the ground must support the installation of LED screens.

Embedded design

We discovered these guidelines after investigating more than 500 LED projects.

1) Both indoors and outdoors can use this installation technique. The display screen is typically on the same horizontal plane as the wall and the full LED screen is typically incorporated in the wall. If the installation's allotted space is insufficient, the screen can adopt a protruding installation and be embellished with a frame to make it flush with the screen.
2) It is appropriate for tiny spaces or locations with high viewing effect requirements, such as entrances to buildings, building halls, lecture halls, small theatres, subway stations, etc.
3) Front upkeep design is typically used for indoor screens.
4) Rear maintenance design is typically used for outdoor screens, however enough room must be set aside on the back of the screen for maintenance.

Upright design

We discovered these guidelines after investigating more than 500 LED projects.

1) This method of installation is typically utilised indoors and can be employed when a wall cannot support the weight of the screen or when a wall is not available. Under the pressure of the bottom and top, it is installed.

2) It is appropriate for malls, structures, lecture rooms, venues, theatres, and other locations.

3) The design of the screen typically favours front maintenance. Rear maintenance cabinets can be used for some large-area screens or unique installation situations, but there must be enough room set aside for maintenance behind the screen.

Column

We discovered these guidelines after investigating more than 500 LED projects.

1) This installation technique is primarily applied outside.
2) It is appropriate for outdoor billboards or informational display boards in streets, malls, hospitals, schools, and other locations.
3) The screen typically has a closed maintenance channel with rear maintenance design that is waterproof.

Hoisting design

We discovered these guidelines after investigating more than 500 LED projects.

1) Both indoors and partially outside frequently employ this installation technique.
2) It can be used at stadiums, terminals, stations, and other locations.
3) The design of the screen typically favours front maintenance. Verify that the top wall or structure can support the weight of the screen before hoisting.

F cantilever/truss

We discovered these guidelines after investigating more than 500 LED projects.

1) This installation technique is frequently applied outside.
2) It is appropriate for media announcements or traffic guidance on highways, motorways, and railroads, among other locations.
3) In most cases, the screen uses a closed maintenance channel and a rear maintenance design. For maintenance, there must be enough room left behind the screen. Sometimes there are time constraints on building and transportation due to the installation location, which causes the construction cost to be somewhat high.

The screen installation process described above is what we want to show you. When installing an LED screen in different locations to improve viewing quality and utility, we must also take into account whether the screen's quality and performance can adapt to the changing environment.

We discovered these guidelines after investigating more than 500 LED projects.

Itc LED video wall system, a rising star in the LED market, has made significant investments in the construction of an independent LED production facility in the field of LED display since its inception. It has also introduced cutting-edge and highly precise SMT fully automatic module production lines to ensure that the production process is on par with industry standards. Finally, Itc LED video wall system has scoured the market for experienced professionals to build a team for developing LED s The itc LED video wall system has created a full R&D, production, building, installation, and after-sales support systems after years of unceasing efforts. It aims to provide consumers with the finest product service and experience by closely regulating the production process and quality of LED goods from every angle.

Material selection (lamp beads, connectors, driver IC, PCB circuit board)
1.Select Kinglight and National Star domestic lamp beads. Less than one in ten thousand lamp beads are damaged, and there is little light deterioration. The lifespan is approximately 10W hours, and the colour won't significantly change in two or three years;
2.To prevent bad contact brought on by oxidation, the wick's connectors are all gold-plated on the surface. The supporting strong and weak current wires are made of international pure copper materials.

Cabinet design
1.Use die-cast aluminium construction with separate property rights. The cabinet is 0.15mm accurate and flat, and the spacing precision below P1.25 is 0.08mm;
2.The cabinet's flatness is seen. The level and verticality of the cabinet are shown in real-time, and the tilt angle is intelligently shown;
3.Wireless connection: Between the cabinets, both hard plug connections and wireless connections are used. There is no cross-wire between the exterior cabinets, and the interior is neat and tidy;
4.Universal cabinet design; a single cabinet may accommodate modules with various spacings. Subsequent product changes just require replacing the module, not the cabinet. You can recycle the cabinet.

R&D and production
1.The independent LED screen R&D team and factory have conducted in-depth technical research and development on the basis of the original LED technology and have created a cutting-edge IoT control function (the LED on the back of the cabinet displays temperature and humidity);
2.Production capacity: Five fully automatic, unsupervised high-precision SMT module production lines are available. After CNC processing, the cabinet will go through three thorough tests to guarantee quality.

Moisture-proof coating technology
1.By using nano-coating technology, the short-circuit issue with lamp beads brought on by humid weather during the rainy season may be effectively reduced;
2.Using intelligent dehumidification technology, the automatic dehumidification, manual dehumidification, and dehumidification duration may be configured through the control software when the screen is not in use for an extended period of time or the working environment is humid.

Construction, installation and maintenance
1.To assure high quality, every LED project includes a skilled construction staff with extensive expertise;
2.Flexible front maintenance: utilising independent built mould opening maintenance tools and modular magnetic attraction technology, it is simple to complete comprehensive front maintenance while guaranteeing flatness.

After-sale technical service
With resident offices set up in provinces and cities all across the nation, standard stationed technical engineers are available all year to assist the local team, and the headquarters' 200 customer service engineers are available around-the-clock to assist clients.

In recent years, the itc LED video wall system has been successfully used in public spaces such as huge squares, schools, government conference rooms, stadiums, financial media centres, urban command centres, securities exchange centres, airports, and other locations. We continue to build our brand among users, provide value to ourselves, and support the growth of the sector.

⋘ back to product knowledge